AFX has over 30 years’ experience in the field of mixing technology. We have a broad range of quality process mixing systems and agitators to suit various industrial applications and provide solutions to all your manufacturing requirements.
PRESSURE OXIDATION
Pressure oxidation (POX), high-pressure oxidation (HiPOX) and ACTIVOX autoclave leaching are practical, industry-standard technologies used to recover metals such as gold, copper, nickel, platinum and uranium.
Once the metals are in solution, the valuable material can be recovered through processes such as electrowinning or chemical precipitation.
Electrowinning, also known as electroextraction, is the process of depositing metals from a solution onto an electrode following leaching.
Chemical precipitationis the process of forming a solid substance from a solution, either by converting the substance into an insoluble form or by changing the solution so that the substance becomes less soluble.
Over the years, AFX has supplied many agitators for autoclaves used in nickel, copper and platinum projects.
AFX has supplied agitators fitted with the P4 impeller, which has a proven track record in gas dispersion, to several projects in the platinum and base metal industries.
Following extensive research and development, our dual-impeller P3 and P4 combination has been installed on numerous plants.
The mechanical design of autoclave agitators requires extensive knowledge of the operating conditions. Understanding and predicting the extreme forces acting on the agitator drive is essential to a successful installation.
The design must accommodate these conditions and protect each component to prevent failures. At AFX, our design programs incorporate this experience to ensure reliable, well-engineered agitators for high-pressure applications.
GAS DISPERSION
Large volumes of gas are injected into vessels or reactors through a dispersion system, such as a sparge ring or pipe. The impeller must be carefully selected to prevent gas flooding while providing effective gas dispersion, blending and solids suspension.
The mechanical design of these systems can be complex, as the agitator is exposed to large fluid forces and resulting shaft deflection. AFX has many years of experience in the process and mechanical design of agitators for these applications.
The AFX high-solidity P4 impeller is well suited to high gas induction rates and is used in applications including:
-
Bio-oxidation and bacterial leaching
-
Dual-impeller systems
TheP4is a downward-pumping, four-bladed, high-solidity hydrofoil impeller that has become a standard in bioleach reactors. It is designed to disperse high volumes of air while maintaining solids in suspension and promoting heat transfer. With a typical solidity ratio of more than 90%, the P4 can operate at high gas volumes without flooding.
TheP3is an upward-pumping, triple-blade, medium-solidity impeller. Originally designed for high-viscosity applications, the P3 has also proven effective in three-phase gas-liquid-solids applications.
The combination of the P3 and P4 dual-impeller system improves oxygen mass transfer in BIOX® and bioleaching processes. The top impeller creates surface air induction, while the mixing pattern of the dual-impeller configuration increases gas hold-up.
This can achieve the required oxygen mass transfer at a lower power input and aeration rate compared with a single-impeller system. The increased surface air induction can also reduce blower capacity and power requirements.
The dual-impeller system provides further mechanical benefits by reducing bending moment, torque and thrust, helping to extend the mechanical life of the agitator.
IRON REMOVAL
Iron is removed through a selective precipitation process involving ferric iron at a controlled pH level.
After the initial metal leaching process, the iron is present as ferrous iron. An oxidation step is then introduced to convert the ferrous iron to ferric iron before precipitation.
For this process, oxidation is achieved by introducing large volumes of air in the presence of sulphur dioxide.
When handling large volumes of air, conventional ring spargers fitted below the impeller can result in impeller flooding and reduced efficiency.
AFX has developed theeight-point bull horn spargerto handle high gas volumes.
With a typical ring sparge, the impeller can flood at around 7% of the impeller pumping capacity. With the AFX system, this figure is increased to over 20%.
The sparger is:
-
Low maintenance
-
Designed to handle high gas rates
In this application, air is used as a carrier gas for the reaction. Gas is injected downwards towards the floor of the tank. As the gas begins to rise, the agitator draws the gas in and holds it down.
Unlike conventional ring sparges, the gas bubbles are not as fine when they are injected into the mixture. This is compensated for by the high gas hold-up created by the combination of the impeller and sparger.
If SO is not being added and sodium metabisulphite (SMBS) is used instead, the system can still achieve the required efficiency.
As a result of these developments, high gas volumes can now be efficiently handled in iron removal processes for base metals.
CYANIDE DETOX
There are several processes available for cyanide destruction, with the INCO method being one of the most commonly used. This process involves the destruction of cyanide in the presence of oxygen and sulphur dioxide.
The oxygen is provided through large volumes of air or pure oxygen, while sulphur dioxide can be supplied as a gas or as a solid reagent, sodium metabisulphite.
To achieve maximum oxygen utilisation during the treatment process, specialised impellers are used. Oxygen utilisation from compressed air can range from20% to 40%, depending on the percentage of solids in the slurry being treated. When pure oxygen gas is introduced, oxygen utilisation can be as high as80%.
PEDESTAL MOUNTED MIXERS
The design of large top entry agitators is often driven more by the requirement for the gearboxes to withstand high bending moments, as opposed to a requirement for high torque. As the gearboxes are always limited by torque and output shaft size selected accordingly, high bending moments often dictate the selection of larger gearboxes. At AFX, we use independent bearing members for these applications, as this design allows the gearbox to be selected on the torque requirements only while the independent bearing member accommodates the high loads produced by the agitator. These pedestals or bearing members are carefully machined in a single setting to ensure accurate alignment of the intermediate shaft, gearbox, and lower shaft. Special five-axis machines are used for this purpose
SOLVENT EXTRACTION
When a pregnant liquor solution comes into contact with an organic solvent, sufficient energy is required to prevent the phases from separating. This energy is introduced into the system by a pump mixer. If too little energy is provided, the phases will separate. This is clearly seen in solvent extraction (SX), where the phases naturally separate within the settler. This is why SX systems are commonly referred to asmixer-settlers.
The mixers need to create a dispersion rather than an emulsion, which can occur when too much energy is introduced.The ideal dispersion uses the minimum energy required to maintain complete dispersion, with no pockets of phase separation.
Since the surface is furthest away from the pump, this is the area where phase separation is most likely to occur. This is useful because the surface of a mix box can be inspected when the lids are removed.
At the minimum power per unit volume required for complete dispersion, the droplets are the largest stable droplets possible. This is ideal when top speed is kept low, as it helps:
-
Minimise fines
-
Improve separation in the settlers
-
Maintain the required dispersion
The minimum power required to prevent phase separation has been determined experimentally. The minimum power per unit volume is a function of residence time and fluid height.
Tall, narrow tanks require more power to resist phase separation than short, wider tanks. This is an important consideration during the design of the mix box.
The design of the mix box needs to consider:
-
Residence time
-
Fluid height
-
Tank geometry
-
Hydraulic efficiency
-
Pump mixer selection
-
Required pump box volume
The best approach is to determine the maximum hydraulic efficiency that can be achieved for the given head and flow, and then determine the required pump box volume.
In addition to selecting the correct pump mixer design, AFX considers all available options when designing the mix box.
We can also assist with selecting the most suitable tank geometry to improve mixer efficiency.